Product Operation

Save the switch’s configuration on the EBR-Module-RS232

Use the switch’s web console to save the switches configuration to the
EBR-Module-RS232. The function is found under “Basic Settings/System File
Upgrade/Backup Media” in the web console.

Load the configuration from the EBR-Module-RS232 to the switch

There are 2 ways to load the configuration from the EBR-Module-RS232 to a
Weidmüller managed Ethernet Switch:

1. Load Automatically

When the EBR-Module-RS232 is plugged in, the switch will automatically
load the configuration from the EBR-Module-RS232 after the switch reboots.
This function can be disabled through the web console under “Basic
Settings/System File Upgrade/Backup Media”, or through the telnet console
under “Basic Settings/Backup Media”.

2. Load Manually

When the EBR-Module-RS232 is plugged in, the configuration can be loaded
manually through the switch’s web console under “Basic Settings/System
File Upgrade/Backup Media”.

NOTE For further details on operation with EBR-Module-RS232 through

the switch’s web console, please refer to the user’s manual of the
used switch.

NOTE The status of the EBR-Module-RS232 may be checked on the

switch’s web console or by observing the switch’s front panel LEDs.

Operation

Switch’s LED status

Save/Load in
progress

FAULT, MASTER, COUPLER LEDs
blink sequentially and circularly

Save/Load successful

FAULT, MASTER, COUPLER LEDs
light off

Save/Load failed

FAULT LED light on, MASTER and
COUPLE LEDs light off


Specifications

Connectors

RS-232 RJ45 port

Power Requirement

3 to 5 VDC, power input via RS-232 RTS

Configuration

via Weidmüller managed Ethernet Switch’s web
console

Casing

PVC molding, IP40

Weight

50 g

Installation

M4 screw (> 4 mm)

Dimension (W × D × H)

32.5 Ч 97 Ч 12 mm

- 4 -