3.

Features

•

Recognition and display of the most frequent installation errors:
short circuit, line/wire interrupt, line/wire mistakes, split pair

•

Self test function and intermittent contact test

•

Error display for each conductor by eight red conductor LED’s and one red LED for the shield (F).

•

Display of no error by green LED (G).

•

One key for ON, OFF and start of the test operation (D).

•

Separate Step Key (H) to display list of multiple errors.

•

Automatic shut off of the IE-CT 30 seconds after the last use of key D or H.

•

Nine switches define the pin assignment (C).

•

Numeric display shows error type (B).

•

9 conductor attachment cord (A) for testing shielded installation lines and cables with up to 8
conductors.

•

IE-CT Mainframe and IE-CT Test Boxes are equipped with RJ45 jacks (E and K) allowing also test
of patch cords.

•

Protected against interference voltages up to 80 V AC/DC (100 V up to 5 minutes).

•

Display of extraneous voltages for each conductor including readout of their polarity.

•

Easy use and interpretation of the test results with given help on the IE-CT housing (I).

•

Display for low battery power.

•

Length of installation cable to be tested up to 1000 m.

•

Automatic test operation is shown by flashing LED (G).

•

Battery polarity reversal protection.

•

Line identification by recognition of up to nine test boxes.

•

Recognition and display for wrong set of pin assignment.

•

Low power consumption for long battery life.