Weidmuller WI GTWY-9: Wireless Gateways v1.2 User Manual

Wi-gtwy-9, Installation guide, Aerial installation

Advertising
background image

Weidmuller Inc., v1.2

WI-GTWY-9

Installation Guide

FCC Notice

This device complies with Part 15.247 of the FCC Rules.

Operation is subject to the following two conditions:

1) This device may not cause harmful interference and

2) This device must accept any interference received, including

interference that may cause undesired operation

Aerial Installation

WI-GTWY-9 Installation

Power supply: (A) 12-24VAC 16VA CSA Certified Class 2

(B) 9-30VDC 16VA CSA Certified Class 2

(C) 13.8V Lead Acid Battery or Gel-cell

Choose option and wire as shown

Host Protocol Connection

Digital Input

Voltage Free

Contact

OR

Transistor

Device

1m minimum

COLINEAR

ANTENNA

MAST

EARTH STAKE

IF GROUND CONDITIONS ARE

POOR, INSTALL MORE THAN

INSTALL AERIAL ABOVE

LOCAL OBSTRUCTIONS

ANT

WI-

GTWY

SURGE

ARRESTOR

(OPTIONAL)

COAXIAL CABLE

WEATHERPROOF

CONNECTORS WITH

“3M 23” TAPE

STRESS RELIEF LOOP

PROVIDE GOOD

GROUND

CONNECTION TO

MAST, MODULE

AND SURGE

ARRESTOR

GND

ANTENNA INSTALLATION

Antennas should be installed by experienced contractors.

WIRELESS GATEWAY

S

U

P

1

S

U

P

2

G

N

D

B

A

T+

G

N

D

D

IO

8

D

IO

7

D

IO

6

D

IO

5

D

IO

4

D

IO

3

D

IO

2

D

IO

1

G

N

D

- +

To Earth

Connection

DC Supply

9-30VDC

16VA

S

U

P

2

S

U

P

1

AC Supply 12-24VAC

Do not earth SUP1 or

SUP2 connections

2A

+

-

Optional 12V

Backup Battery up

to 100 Amphour

+ -

Digital Output

Max 30VDC, 500mA

DC Relay Supply

NOTES

1. DIO channels can be

wired as either inputs or

outputs.

2. All I/O must be SELV.

CAUTION!

For continued

protection against

risk of fire, replace

the module fuse only

with the same type

and rating

WARNING !

EXPLOSION HAZARD

DO NOT DISCONNECT

WHILE CIRCUIT IS LIVE

UNLESS AREA IS

KNOWN TO BE NON

HAZARDOUS

WI-GTWY-9-xx

To Earth

Connection

S

U

P

1

S

U

P

2

G

N

D

ONE EARTH STAKE