Monitoring the vacuum gauge, Controlling the lifter and load, In case of power failure – Wood’s Powr-Grip PFHL89AC User Manual

Page 14

Advertising
background image

Rev 26.0/1-14

12

PF-AC: #35130

Monitoring the Vacuum Gauge

The vacuum gauge must remain completely visible to the operator, so that it can be monitored

throughout the entire lift.

WARNING: Vacuum gauge must be visible to operator throughout entire lift.

The lifter’s vacuum pump runs continuously to maintain sufficient vacuum for lifting the

maximum load weight. If the vacuum system experiences leakage while the lifter is attached to

the load, the vacuum gauge signals the reduction in vacuum to the operator. Make sure the
vacuum gauge shows a vacuum level of 16" Hg [-54 kPa] or higher while you are lifting a load.
If not, move away and stay clear of the load until it can be lowered to the ground or a stable

support.

WARNING: Stay clear of any suspended load while vacuum level is lower than

16" Hg [-54 kPa].

Discontinue lifter use until the cause of the vacuum loss can be determined. If the vacuum level

remains lower than 16" Hg [-54 kPa] when the lifter is attached to clean, smooth, nonporous
materials, the leakage is likely to be in the vacuum system. In this event, perform the V

ACUUM

T

EST

(see MAINTENANCE) and inspect the vacuum pads for damage (see MAINTENANCE: V

ACUUM

P

AD

M

AINTENANCE

: Inspection). If the vacuum loss cannot be remedied immediately, perform

inspection and maintenance as needed to identify and correct any deficiency before resuming

normal operation of the lifter.

Controlling the Lifter and Load

When the vacuum gauge indicates that the lifter is ready, use the hoisting equipment to raise the

lifter and load as needed to clear any obstacles in their path. Use the control handles to keep the

lifter and load in the desired orientation while they are suspended from the crane. Once
sufficient clearance is established, the load can be rotated or tilted as desired (see T

O

R

OTATE THE

L

OAD

E

DGEWISE

or T

O

T

ILT THE

L

OAD

to follow).

In Case of Power Failure

The lifter is equipped with a vacuum reserve tank, designed to maintain vacuum temporarily in

case of a power failure.

WARNING: Stay clear of any suspended load in the event of a power failure.

Although the lifter is designed to support the load for at least 5 minutes without power, this

depends on many factors, including the condition of the load and the lifter’s vacuum system (see

INTENDED USE: L

OAD

C

HARACTERISTICS

and MAINTENANCE: V

ACUUM

P

AD

M

AINTENANCE

,

V

ACUUM

T

EST

). If a power failure occurs, keep all personnel clear of the suspended load until it can safely

be placed on the ground or a stable support. Correct any deficiency before resuming normal
operation of the lifter.