Acuum, Aintenance – Wood’s Powr-Grip PFHL89AC User Manual

Page 23

Advertising
background image

Rev 26.0/1-14

21

PF-AC: #35130

V

ACUUM

P

UMP

M

AINTENANCE

G

AST

3032

&

2032

(for Gast pump nos. 3032-101A-G609X and 2032-101-G616X)

WARNING: Before proceeding with any maintenance, disconnect power source;

allow pump to cool; and vent any vacuum or pressure remaining

in vacuum system.

If the vacuum pump takes too long to attain full vacuum, it may require maintenance, as directed in the

following disassembly/reassembly procedure. Service or replace air filters and vanes as necessary to

obtain acceptable pump performance (see service kit in REPLACEMENT PARTS LIST). Note: Inspect air

filters after no more than 500 hours of operation; dirty filters must be cleaned or replaced.
1) Remove the retainer bolts (7 & 8) from the vacuum pump.












2) Remove the retainer plate (6) and insert plate (5) by lightly tapping on them with a small hammer.

Note: Do not use a screwdriver to remove these plates, because it could damage them.

3) Before removing the existing vanes (3), note the direction of the beveled edge, in order to install the

new vanes in the same orientation. Do not try to remove the rotor, because it can only be serviced by

the manufacturer.

4) Spray the bore and rotor with a suitable, nonpetroleum-based flushing solvent. Use a clean, dry cloth

to remove flushing solvent from these parts.

5) Place the new vanes (3) in the rotor slots with the beveled edge in the correct orientation (see step

3). Note: Vanes may become damaged or broken if installed incorrectly.

6) If the air filters (4) appear dirty, clean them with soapy water or replace them all together, depending

on their condition. After cleaning the filters, dry them with compressed air. Since moisture can

damage the pump, be sure to avoid introducing any moisture into the pump. When the filters are

completely dry, reinstall them in the rotor housing. Otherwise, install new filters.

7) Place a sheet of fine emery cloth on a smooth, flat surface and rub both sides of the insert plate (5)

on the emery cloth to remove any burrs. Use a clean, dry cloth to remove any dust from the insert
plate. Reinstall the insert plate, placing the unused side facing the pump vanes.

8) Repeat step 7 with the face of the retainer plate (6). Use a clean, dry cloth to remove any dust from

the retainer plate and reinstall it.

9) Reinstall the retainer bolts (7 & 8) and tighten them to 28-36 in-lbs [3.1-4.1 N-m] of torque.

1 MOTOR W/ROTOR HOUSING

2 CAPACITOR

3 VANES (4x)

4 AIR FILTERS (2x)

5 INSERT PLATE

6 RETAINER PLATE

7 LONG RETAINER BOLT (3x)

8 SHORT RETAINER BOLT (5x)