Ift and, Ove the – Wood’s Powr-Grip MT1TL6FAIR User Manual

Page 11

Advertising
background image

Rev 6.0/12-12

9

MT1-AIR: #35080

Vacuum Level on Other Surfaces

When the lifter is attached to contaminated, rough or porous load surfaces, it may not be able to

maintain a vacuum level in the green range on the vacuum gauge, due to leakage in the seal
between the vacuum pad and the load surface. In the case of contamination, thoroughly clean

the contact surfaces of the load and the vacuum pad (see MAINTENANCE: V

ACUUM

P

AD

M

AINTENANCE

: Cleaning), and reapply the lifter to the load. If the load has rough or porous

surfaces,

the operator must conduct a test to determine whether the lifter is designed

to lift the load

, as follows:

1) Make sure the lifter's vacuum generating system is functioning correctly (see MAINTENANCE:

V

ACUUM

T

EST

).

2) Apply the vacuum pad to the load as previously directed.
3) When the vacuum level registers above 16" Hg [-54 kPa] on the vacuum gauge (see T

O

L

IFT

AND

M

OVE THE

L

OAD

: Load Capacity and the Vacuum Gauge to follow), move the slide on the

vacuum control valve to the “OFF” position (

towards

regulator).

4) Raise the load a minimal distance, to assure that it is supported by the lifter.
5) Monitor the vacuum gauge while the load is suspended for 5 minutes:

The lifter must

maintain a minimum vacuum level of 10" Hg [-34 kPa] during this time.

If not, the

load does not possess the characteristics required for using this lifter.

3

T

O

L

IFT AND

M

OVE THE

L

OAD

Load Capacity and the Vacuum Gauge

A lifter’s Maximum Load Capacity is rated at a vacuum level of 16" Hg [-54 kPa] (see

SPECIFICATIONS). Vacuum higher than this level registers in the green range on the vacuum
gauge, to indicate that the lifter is ready to lift the maximum load weight.

WARNING: Never attempt to lift load unless vacuum level registers higher than

16" Hg [-54 kPa].

Do not attempt to lift the load while vacuum registers lower than 16" Hg [-54 kPa]; such an

attempt could result in a load release and possible injury to the operator.

Monitoring the Vacuum Gauge

The vacuum gauge must remain completely visible to the operator, so that it can be monitored

throughout the entire lift.

WARNING: Vacuum gauge must be visible to operator throughout entire lift.

The lifter’s vacuum pump runs continuously to maintain sufficient vacuum for lifting the

maximum load weight. If the vacuum system experiences leakage while the lifter is attached to

the load, the vacuum gauge signals the reduction in vacuum to the operator. Make sure the
vacuum gauge shows a vacuum level of 16" Hg [-54 kPa] or higher while you are lifting a load.
If not, move away and stay clear of the load until it can be lowered to the ground or a stable

support.

3

Certain load materials are too rough or porous to allow the lifter to form a seal which can be maintained for 5 minutes without

power. However, in geographical locations where CE Standards do not apply, it may be possible to use the lifter to lift such loads.
Contact Wood’s Powr-Grip for more information.