Hutoffs, Pply the, Ads to a – Wood’s Powr-Grip MT10HV11FDCO User Manual

Page 11

Advertising
background image

Rev 19.0/1-13

9

MT-HV11FDCO: #35093

T

O

U

SE

P

AD

S

HUTOFFS

Each shutoff on the pad frame controls the vacuum line to the adjacent vacuum pad. By

activating or deactivating the vacuum flow at specific pads, the operator can use the lifter to
handle loads of various weights and dimensions (see Load Capacity and Pad Spread in
SPECIFICATIONS). In addition, certain pads may be deactivated in order to avoid holes in the

load surface. To support the maximum load weight and larger load dimensions, all pads must be
activated; for smaller weights and dimensions, some pads may be deactivated,

provided that

the lifter still has sufficient capacity to support the load

(see INTENDED USE: L

OAD

C

HARACTERISTICS

).

WARNING: Closing any pad shutoff reduces lifting capacity.

To activate a pad, open the pad shutoff (place valve lever

parallel

with

vacuum line); to deactivate a pad, close the pad shutoff (place valve lever

perpendicular

to vacuum line). To calculate the lifting capacity when some

pads are deactivated, consult the Per-Pad Load Capacity rating (see

SPECIFICATIONS) and multiply by the number of pads currently
activated. Always activate pads in a symmetrical configuration, to keep
the lifter balanced while lifting, and use as many pads as possible for

each load being lifted, to maximize lifting capacity and to minimize load
overhang.

T

O

A

PPLY THE

P

ADS TO A

L

OAD

Powering up the Vacuum Package

Place the power switch in the ON ( ) position (blue indicator light remains illuminated while

power is engaged). The power switch must remain in the ON position while operating the lifter.

5

WARNING: Never turn power off while operating lifter.

Placing the power switch in the OFF ( ) position during lifter operation could result in the

release of the load and possible injury to the operator.

Positioning the Lifter on the Load

Make certain that the contact surfaces of the load and all vacuum pads are free of any

contaminates that could prevent the pads from sealing against the load (see MAINTENANCE:
V

ACUUM

P

AD

M

AINTENANCE

).

The lifter is designed to automatically carry the load in an upright orientation. Center the pad

frame from left to right on the load. Determine which will be the top edge of the load while

lifting, and position the long row of vacuum pads near that edge.

6

This position will maximize

stability while lifting the load. Make sure that all activated pads will fit entirely on the load’s
contact surface (see SPECIFICATIONS: Pad Spread) and that they will be loaded evenly while

lifting (see SPECIFICATIONS: Per-Pad Load Capacity).

5

If a vacuum pump or any other powered component fails to function while the power switch is in the ON position, examine

each circuit breaker (adjacent to power switch) to determine whether it has interrupted the electrical circuit to the component.

Although the operator can reset the circuit breaker, the power interruption may indicate an electrical problem that requires
attention. Correct any deficiency before resuming normal operation of the lifter (see wiring diagram provided).

6

This is the

only row of pads on models MT4HV11FDC and MT6HV11FDC.

CLOSED

PAD SHUTOFF VALVE

Advertising
This manual is related to the following products: