Acuum – Wood’s Powr-Grip VL411LDC User Manual

Page 20

Advertising
background image

Rev 17.0/12-12

18

VL411LDC: #35162

V

ACUUM

T

EST

Test the vacuum system for leakage routinely, as directed in the preceding I

NSPECTION

and

T

ESTING

S

CHEDULES

.

1) Clean the face of each vacuum pad as previously directed (see V

ACUUM

P

AD

M

AINTENANCE

:

Cleaning).

2) Apply the lifter to a clean, smooth, nonporous surface. The surface should be flat or possess

no more curvature than the lifter is designed for (if any).

10

When the pumping cycle is

completed, the vacuum level should register above 16" Hg [-54 kPa] on the vacuum gauge (if
not, see V

ACUUM

S

WITCH

A

DJUSTMENT

to follow).

3) After the vacuum pump stops running, leave the pads attached to the surface and interrupt

the energy flow from the battery: Disconnect the electrical connector uniting the battery to

the vacuum generating system.
Note: After the vacuum test is completed, move the valve handle to the “RELEASE” position

(power

off

) before reconnecting the battery.

4) Monitor the vacuum gauge:

The vacuum level should not decrease by more than 4" Hg [-14

kPa] in 10 minutes.

WARNING: If lifter fails vacuum test, discontinue use immediately.

Correct any deficiency in the vacuum system before using the lifter. Contact Wood’s Powr-Grip

or an authorized dealer for assistance.

10

Any test material used must be fully and independently supported, and capable of bearing the lifter’s weight. Do not use

the lifter to lift the test material during the vacuum test.