Specifications – Wood’s Powr-Grip VL411LDC User Manual

Page 3

Advertising
background image

Rev 17.0/12-12

1

VL411LDC: #35162

SPECIFICATIONS

Model Number:

VL411LDC

Description:

Designed for use with a crane or other hoisting equipment, the VL411LDC lifter

employs vacuum to hold a load for lifting in the upright orientation.

Power Source:

12 volts DC, 10 amps (with Thomas pump) or 3 amps (with Dynaflo pump)

Battery Capacity:

7 amp-hours

Vacuum Pads:

Four 11" [28 cm] nominal diameter, lipped (Model G3370), standard rubber,

spring-mounted (¼" [7 mm] travel), with #60 filter screen

Pad Spread:

23½" x 58" [597 mm x 1474 mm] to outer edges

Load Capacity:

(rated at 16" Hg [-54 kPa] on clean, smooth, nonporous flat surfaces

1

)

Per-Pad:

175 lbs [80 kg]

Maximum:

700 lbs [320 kg]

Lifter Weight:

60 lbs [27 kg]

Vacuum Pump:

Diaphragm type, 1 SCFM [28 liters/minute] nominal airflow

Vacuum Reserve Tank:

Vacuum reservoir helps prevent immediate vacuum loss in case of power failure

and extends battery life by reducing pump cycles required to maintain vacuum.

Vacuum Gauge:

Dial gauge indicates current vacuum level in positive inches of Hg and negative

kPa.

Low Vacuum Warning Light: Red light is energized until vacuum level is sufficient to lift maximum load

weight (higher than 16" Hg [-54 kPa]) and whenever vacuum loss causes pump

to re-engage.

Options:

See appendix for instructions about optional features.

Operating Elevation:

Maximum = 6000 feet [1828 meters]

Operating Temperatures: 32° to 104° F [0° to 40° C]
Service Life:

This lifter is designed to have a service life of at least 20,000 lifting cycles, when

used and maintained as intended. Vacuum pads, filter elements and other

wear-out items are excluded; see MAINTENANCE and REPLACEMENT PARTS

LIST for more information. For the D

ISPOSAL OF THE

L

IFTER

after its service life,

see INTENDED USE.

ASME Standard BTH-1:

Design Category "B", Service Class "0" (see www.powrgrip.com for more

information)

Wiring Diagram:

The following wiring diagrams are attached for reference in servicing the lifter

or trouble-shooting a deficiency:

705-W01 [W01]

,

705-W01 [D-W01]

!!-CE-!! Note: This symbol appears in the

INSTRUCTIONS

manual only when requirements of a CE Standard are

different

from requirements of other standards that also apply to this vacuum lifter. CE requirements are

mandatory in geographical areas where CE Standards apply, but may be optional in other locations.

1

Load Capacity is based on a friction coefficient of 1; see MAINTENANCE: V

ACUUM

P

AD

M

AINTENANCE

: Friction Coefficient for

additional information.

Advertising