8

VLPL4-AC: #35165

WARNING: Closing any pad shutoff reduces lifting capacity.

To activate a pad, open the pad shutoff (place valve lever

parallel

with

vacuum line); to deactivate a pad, close the pad shutoff (place valve lever

perpendicular

to vacuum line). To calculate the lifting capacity when any

pads are deactivated, consult the Per-Pad Load Capacity rating (see
SPECIFICATIONS) and multiply by the number of pads currently
activated. Always activate pads in a symmetrical configuration, to keep
the lifter balanced while lifting, and use as many pads as possible for

each load being lifted, to maximize lifting capacity and to minimize load
overhang.

T

O

A

PPLY THE

P

ADS TO A

L

OAD

Generating Vacuum Flow

Place the power switch in the "ON" position. This engages the vacuum pump, causing air to be

drawn immediately at the vacuum pads.

4

WARNING: Never turn power off during operation; keep pump running

throughout lift.

The lifter is designed for the vacuum pump to run continuously. Placing the power switch in the

"OFF" position during lifter operation could result in the release of the load and possible injury to
the operator (see T

O

L

IFT AND

M

OVE THE

L

OAD

: In Case of Power Failure to follow).

Positioning the Lifter on the Load

Make certain that the contact surfaces of the load and all vacuum pads are free of any

contaminates that could prevent the pads from sealing against the load (see MAINTENANCE:
V

ACUUM

P

AD

M

AINTENANCE

).

The lifter must be attached only to vertically oriented loads. Center the pad frame from left to

right on the load, and position the uppermost activated pads near the top edge. This position

will maximize stability while lifting the load. Make sure that all activated vacuum pads will fit
entirely on the load’s contact surface (see SPECIFICATIONS: Pad Spread) and that they will be
loaded evenly while lifting (see SPECIFICATIONS: Per-Pad Load Capacity). Then apply the lifter

to the load until the pads seal against the contact surface.
Note: If a vacuum pad has been lying against a hard object (as during shipping), it may be

slightly distorted. Although initially it may be difficult to apply the pad to a load, this condition
should correct itself with continued use.

4

If the vacuum pump or any other powered component fails to function while the power switch is in the "ON" position, make

sure the lifter is connected correctly to an appropriate power source, as directed in the ASSEMBLY section. If so, examine each
circuit breaker (adjacent to power switch) to determine whether it has interrupted the electrical circuit to the component.

Although the operator can reset the circuit breaker, the power interruption may indicate an electrical problem that requires
attention. Correct any deficiency before resuming normal operation of the lifter (see wiring diagram provided).