Assembly – Wood’s Powr-Grip VLPL411LAC User Manual

Page 6

Advertising
background image

Rev 15.0/12-12

4

VLPL4-AC: #35165

ASSEMBLY

1) Open the shipping container and remove all materials for restraining or protecting the vacuum

lifter. Save the container for use whenever the lifter is transported.

2) Suspend the lifter from a crane as follows: Select a hoisting equipment (crane and hoist,

when applicable) rated to carry the maximum load weight plus the lifter weight (see
SPECIFICATIONS: Maximum Load Capacity and Lifter Weight).
Note: Any application of the lifter must conform to all statutory or regulatory standards that

relate to the hoisting equipment when used in its geographical location (eg, relevant OSHA

standards in the USA).
Tilt the lifter upward until the pad frame is in a vertical orientation, resting on the integrated

parking feet. Then attach the hoist hook to the lift spool.

WARNING: Hoisting equipment hook must be fitted with restraining latch to

prevent lift spool from slipping off under any circumstances.

Use the hoisting equipment to raise the lifter out of the shipping container, being careful to

avoid damaging any vacuum pads. A hoist control pendant can be attached to the lifter by

inserting it into the pendant basket provided. Remove the pad covers and save them for use
whenever the lifter is stored.

3) Connect the power cable from the lifter to the power source as follows: Identify the label

indicating the voltage range (V) and frequency (Hz) required to power the lifter (located

where power cable connects to lifter). Wire the female connector provided to an appropriate
current-protected power source.

WARNING: Wiring must be done by qualified personnel, taking all appropriate

safety precautions.

Note: Be advised that brown-outs, overtaxed generators, extension cords, and other

conditions can reduce power input at the lifter. If the lifter does not receive adequate power

while lifting, this could result in an unexpected load release and a risk of injury to the
operator or others.

WARNING: Lifter that does not receive adequate power while lifting could

experience unexpected load release.

The power source must be equipped with a ground fault circuit interrupter, in order to reduce
the risk of electrical shocks.

WARNING: Power source must be equipped with ground fault circuit interrupter.

Make certain the power cable is routed so that it does not become tangled while operating

the lifter or hoisting equipment. Then push the power cable’s male connector into the female
connector and twist to secure them together. Now the lifter is operational.

4) Perform Operational and Load Tests for the lifter as directed in MAINTENANCE: T

ESTING

S

CHEDULE

.

Advertising
This manual is related to the following products: