Rockwell Automation 8-545 Plug In Solid State Relay User Manual

Installation instructions photoswitch

Advertising
background image

INSTALLATION INSTRUCTIONS

PHOTOSWITCH

PLUG IN SOLID STATE RELAY, BULLETIN 8-545/8-585

IMPORTANT: SAVE THESE INSTRUCTIONS FOR FUTURE USE. FOR ADDITIONAL INFORMATION REFER TO PUBLICATION PGĆ9000

BULLETIN NUMBER

TYPE

VOLTAGE SUPPLY

LOAD CURRENT

LEAKAGE

(off State)

RESPONSE TIME

(off State)

8-545

Triac

75-140-VAC

1A

6 mA

8 ms

8-585

F.E.T

0-120 VAC/DC

30mA

10 µA

1 ms

8-545

SPECIFICATIONS

Line Transient Protection

MOV varistor

. . . . . . . . . . . . . . . . . . .

Approvals

UL Listed and CSA Certified

. . . . . . . . . . . . . . . . . . . .

Contracts

1 Normally Open

. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

Ambient Temperature Range

–20

°F to 135°F (–28°C to 57°C)

. .

Load Current

Continuous

1 A

. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

50% (Max) Duty Cycle

2 A

. . . . . . . . . . . . . . . . . . . . . . . . . . . . .

10% (Max) Duty Cycle

4 A

. . . . . . . . . . . . . . . . . . . . . . . . . . . . .

Surge 1% (Max) Duty Cycle

10 A

. . . . . . . . . . . . . . . . . . . . . . . .

Input (control) voltage to operate

14–30VDC

. . . . . . . . . . . . . . . .

Input (control) current to operate

3 – 6 mA

. . . . . . . . . . . . . . . .

Input to output isolation

1000 Megohms and 1500 VAC

. . . . . . .

ALL 22 SERIES BASES

ALL 42RL SERIES CONTROLS

TERMINALS

1C

1NO

1NC

LOAD 75-140 VAC

TERMINALS

2C

2NO

2NC

LOAD 75-140 VAC

LOAD

LOAD

EXTERNAL CONNECTION DIAGRAM

INTERNAL SCHEMATIC

INPUT

OUTPUT

N.O.

B

A

6

9

14V MIN

TO

TERMINALS

+

-

10A FUSE

8-585

SPECIFICATIONS

Overvoltage Protection

MOV varistor

. . . . . . . . . . . . . . . . . . . . .

Approvals

UL Listed and CSA Certified

. . . . . . . . . . . . . . . . . . . .

Contracts

Form A (SPST) Normally Open

. . . . . . . . . . . . . . . . . . .

Ambient Temperature Range

–40

°F to 150°F (–40°C to 65°C)

. .

Maximum Operating Voltage

± 200VDC or Peak AC

. . . . . . . . .

Maximum Continuous Load Current

30mA

. . . . . . . . . . . . . . . .

Maximum Peak Load Current

100mA

. . . . . . . . . . . . . . . . . . . . .

Short Circuit Load Protection

None

. . . . . . . . . . . . . . . . . . . . . .

Minimum Load Current

None

. . . . . . . . . . . . . . . . . . . . . . . . . . .

Maximum On Resistance

70 Ohms

. . . . . . . . . . . . . . . . . . . . . . . . .

Minimum Voltage Input for Reliable Operation

17VDC

. . . . . . .

Input Current Drain

25 mA at 30VDC

. . . . . . . . . . . . . . . . . . . . .

Isolation Voltage

2500 VAC

. . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

EXTERNAL CONNECTION DIAGRAM

ALL 22 SERIES BASES

1C

1NO

1NC

TO PROGRAMMABLE

CONTROLLER

INTERFACE

ALL 42RL SERIES CONTROLS

AND 60-1691 MULTI-MODULE OUTPUT BASE

2C

2NO

2NC

TO PROGRAMMABLE

CONTROLLER

INTERFACE

INTERNAL SCHEMATIC

N.O.

B

A

6

9

TO

TERMINALS

(+)

(-)

Advertising