Rockwell Automation 20P PowerFlex DC Drive - Frame D Bimetal Thermostat User Manual

Rockwell Automation Equipment

Advertising
background image

Publication 20P-IN061A-EN-P

PowerFlex® DC Drive

Frame D Bimetal Thermostat
Installation Instructions

What This Kit Includes

Bimetal thermostat and cable with connector

Thermal grease

Tools That You Need

Flathead screwdriver

Hexalobular screwdriver

Torque wrench

What You Need to Do

The bimetal thermostat is located on the heatsink of the U phase SCR leg
assembly in the drive. To install the bimetal thermostat:

❐ Step 1: Remove power from the drive

❐ Step 2: Remove the protective cover and open the control panel

❐ Step 3: Remove the existing bimetal thermostat

❐ Step 4: Install the new bimetal thermostat

❐ Step 5: Install the protective cover, close the control panel and document

the change

ATTENTION: Only qualified personnel familiar with DC drives
and associated machinery should plan or implement the installation,
start-up and subsequent maintenance of the system. Failure to comply
may result in personal injury and/or equipment damage.

ATTENTION: To avoid an electric shock hazard, ensure that all
power to the drive has been removed before performing the following.