Step 4: install the new bimetal thermostat – Rockwell Automation 20P PowerFlex DC Drive - Frame D Bimetal Thermostat User Manual

Page 8

Advertising
background image

Publication 20P-IN061A-EN-P

8

10. Place the SCR leg assembly right side down on a work surface and

disconnect the wires from the connector mounted on the middle, left-side of
the assembly.

11. Remove the two hexalobular screws that secure the thermostat to the heat

sink and remove the thermostat.

Step 4: Install the New
Bimetal Thermostat

Install the new bimetal thermostat in the reverse order of removal as detailed in
Step 3:

Remove the Existing Bimetal Thermostat on page 4

.

Important: Apply thermal grease to the bottom of the new bimetal thermostat

before installation.

• Tightening torque for the bimetal thermostat is 1.0 N•m (8.9 lb•in).

• Tightening torque for the SCR leg assembly is 4.5…5.0 N•m (40.0…44.4

lb•in).

• Tightening torque for the SCR module input and output terminals to the fuse

terminals and DC output bus bars is 45 N•m (398 lb•in).

Remove screws

Disconnect wires from connector

Advertising