Publication 20P-IN061A-EN-P

4

Step 3: Remove the
Existing Bimetal Thermostat

Note: Regenerative drives have two sets of terminals (front and back) on each
SCR module for each input phase (U, V, and W). Non-Regenerative drives only
have one terminal for each input phase.

1. Disconnect the gate lead wires from the connector at the top the U phase

(left) SCR leg assembly (for regenerative drives, there are two sets of gate
leads and connectors).

2. Disconnect the wires for the bimetal thermostat from the connector

mounted on the middle of the U phase SCR module leg assembly.

3. Disconnect the wires for the capacitors and resistors from the connector

mounted at the bottom of the SCR module leg assembly.

Disconnect gate lead

wire connectors

Disconnect thermostat

wire connector

Disconnect capacitor and

resistor wire connector

SCR module assembly

White

Red

White

Red

Gate lead wire
color order