8.0 GENERAL MAINTENANCE

No general maintenance is required other than adhering to the Cleaning Procedure instructions.

9.0 TROUBLESHOOTING

9.1 LOW WATER LEVEL

Proper water level must be maintained within the jacket for the kettle to operate. Depletion of
water may occur from excessive opening of or leakage through the safety relief valve.

If water is below required operating level, either initially at start-up or during use, the kettle will
automatically shut off, and the LOW WATER signal light will come on.

In order for the kettle to operate, the following procedure must be followed.

The kettle must be cool before proceeding with the following steps.

1. Trip the safety relief valve lever to relieve all pressure from the kettle jacket.

2. At exterior rear of kettle jacket remove nut from Air Vent.

3. Insert funnel into Air Vent opening and slowly add the indicated amount of clean water for:

CAPACITY

ADD:

COMPLETELY EMPTY, ADD:

20 gallon kettle

140 ounces

4.14 litres

376 ounces

11.12 litres

30 gallon kettle

150 ounces

4.44 litres

504 ounces

14.90 litres

40 gallon kettle

220 ounces

6.50 litres

548 ounces

16.20 litres

60 gallon kettle

250 ounces

7.39 litres

586 ounces

17.33 litres

80 gallon kettle

340 ounces

10.05 litres

850 ounces

25.12 litres

100 gallon kettle

420 ounces

12.42 litres

1088 ounces

32.17 litres


4. Replace Air Vent nut.

5. Follow Air Venting Instructions in section (9.5).

6. Continue normal Operating Procedure of kettle.