WARNING: Disconnect the electrical power supply and place a tag at the
disconnect switch to indicate that you are working on the circuit.


ELECTRICAL CONNECTIONS

A Control Box with power supply equivalent to electrical rating of the kettle should be located
conveniently nearby.

Remove the wiring compartment cover and make electrical connections per wiring diagram located
inside the control housing cover panel. A waterproof electrical connection from power supply to
rear of control housing must be provided.

Kettle must be grounded in accordance with requirements of the National Electrical Code or
applicable local codes.

Ground kettle to terminal provided in control housing.

Once proper connections are made, replace wiring compartment cover, turn power ON and check
for proper operation.

SERVICE CONNECTIONS

All internal wiring for the kettle is complete.

If faucet is provided connect water supply and check for proper operation.

INSTALLATION CODES AND STANDARDS

Your electric tilting kettle must be installed in accordance with:

1. State, provincial and local codes, or in the absence of local codes, with: C.S.A. C22.1

Canadian Electrical Code, Part 1, or in the U.S.A., the National Electrical Code ANSI/NFPA-70
(latest edition).


2.

ANSI NFPA Standard #96, “Vapor Removal from Cooking Equipment,” (latest edition),
available from the National Fire Protection Association, Batterymarch Park, Quincy, MA,
02269.