Figures 4.5 - 4.6 show examples of some typical output interfaces.

Figure 4.5 – Isolated Connection to External Circuit


Figure 4.6 – Isolated Connection to External Devices

EXTERNAL CIRCUIT

0-30 Vdc @ 8A max.

0-120 Vac @ 10A max.

232DRIO

+12 Vdc

N/C

N/O

Common

Common

EXTERNAL CIRCUIT

232DRIO

+12 Vdc

N/C

N/O

Common

1K

+5 Vdc

0-30 Vdc @ 8A max.

0-120 Vac @ 10A max.