Identical Positive and Negative Voltages With a
Separate Common (Refer To Fig. 15)

Another typical “split supply” application is when a circuit

uses operational amplifiers (op-amps). Typically, identical
positive and negative voltages are required to power op-amp
circuits. Using both supplies and the series tracking mode of
operation, identical positive and negative voltages with a
separate common are obtained as follows:

1. Select the Tracking Series operating mode and set A/B

Metering switch to monitor the “A” supply.

2. Set the desired voltage using the “A” VOLTAGE

controls.

3. Connect a ground wire between the “A” supply negative

terminal and the GND (green) terminal.

4. Turn off the power supply and the equipment to be

powered during hook-up.

5. Connect the positive polarity input of the circuit to be

powered to the positive (red) terminal of the “A” supply
and connect the negative polarity of the circuit to the
negative terminal of the “B” supply. Connect the circuit
ground to the ground terminal of the “A” supply, the
positive terminal of the “B” supply, or the GND (green)
terminal.


Fig. 15. Typical Hook-Up Using Identical Positive

and Negative Voltages with a Separate Common.