DD MM YY XX
When working with an Aaton or Aaton system cameras, or setting the Internal
RTC this format must be used.

1.3.7 The AMPS configuration

DD MM UR RR
Use this format when more identification numbers are required.

1.3.8 The Time Field


The time field has the following fixed configuration:
H= Hours M= Minutes S= Seconds F= Frames

HH MM SS FF

When the display is running the frame field is changing at the frame rate. In
the set mode the FF position can contain the following digits and letters which
indicate the frame rate selected by the DIP-switches or modes for setting the
RTC.

1.3.9 The Frame (FF) Digits



Display 24 25 23

29 2d 30 3d ct cd


Fps 24 25 23.98 29.97 29.97 30 30 set set

Drop

Drop RTC RTC from

Frame

Frame Gen. TC Manual Displ.

Note:

The frame rate displayed is an indication of the DIP-switch setting and cannot

be changed by the cursor.


1.3.10 The CD and CT functions

The ct or cd function can be selected in the FF position.The slate must also
be in the generator /RTC mode.

Select ct

When Load is implemented the RTC is set from the generator time
and date.

Select cd

When Load is implemented the RTC is loaded from the current
display time and date. (Set manually)

Select Fps (DIP-switch value shown)