Ambient Wireless TC Slate - ACD 301 RF User Manual

Page 5

Advertising
background image

5

1.1.1 The DIP-switches

There are two switch field’s inside. One with 12 DIP-switches and one with 4 DIP-
switches. Their functions are outlined in this chapter. It is important to note that
changes made to the DIP-switches (12 switch-field) 1, 2 and 3 are activated only
after a power-down, power-up cycle. Switches 4 through 12 take effect at once.

DIP-switch with 12 switches:

OFF


ON

1 2 3 4 5 6 7 8 9 10 11 12


Frame rate
SW

24 Frs

25 Frs

30 Frs

29.97 Frs

1

ON

OFF

OFF

ON

2

OFF

OFF

ON

ON


3

ON

Drop Frame with 29.97 and 30 frames

Note. Drop Frame with 24 is slow 24 (23.98frs!)

Drop Frame with 25 in Reader mode is Enhanced reader (see
section 3.4)

Operating modes

SW

Gen

Gen/ RTC

Read/Gen

Read

4

OFF

OFF

ON

ON

5

OFF

ON

OFF

ON

Display modes

6

ON

Time code only displayed

.

No transition to userbits when slate closed.

Display userbits with RED button.

OFF

Normal slate function

.

Slate open

Time code display.

Slate closed

Display userbits for 2 secs,

or userbits with RED button.


7

ON

Clapped time shown

for 2 minutes.

OFF

No clapped time displayed

.

Note: With SW 7 down LED display shuts off after 3 minutes.

8

ON

Advance display

frames as selected by switches 9. 10. 11.

OFF

Retard display

frames as selected by switches 9.10.11.

Frs 0

1

2

3

4

5

6

7

9

1’s

0

1

0

1

0

1

0

1

10

2’s

0

0

1

1

0

0

1

1

11

4’s

0

0

0

0

1

1

1

1

12

OFF Running time code shown when clapstick lifted.

ON

Userbits shown for one second.