PAGE 11

TP10432A-EN

The center notches should seat on the second set of

locating pins. Pivot the fold plate hold-downs back into
position to secure the fold plates.

Turn the handwheel to be sure that the fold plates

are properly installed and not rubbing on the fold rolls.

Plug the fold pan connectors into the side frame.

(See figure 4.5-1)

5.0 ELECTRICAL ACCESS

WARNING

Turn off the main power switch(See figure 5.0-1).

Unplug the AC power cord before attempting any
electrical repair.

The electrical controls are located in the left-hand

side cover. The handwheel must be removed for access to
these controls.

The cover can be removed by taking out the four

screws located on the inside of the frame.

Figure 4.5-1

Figure 5.0-1

Main Power/Reset
Switch

6.0 OPERATION

6.1 The Main Power/Reset Switch

The main power/reset switch (Figure 6.1-1) will

completely shut off all power to the operating system. This
will stop everything immediately.

Main Power/Reset
Switch

Figure 6.1-1

6.2 Starting the Production Job

The production job may be started after preparing the

folder by:

Setting the sheet size
Loading the feed table
Selecting the fold type
Setting Cross Carrier Side Guide

Folding may be stopped by pressing the “SHEET

START” button a 2nd time on the Parallel Unit.

6.3 Check Squareness of Fold

Examine the folded sheets on the stacker to make sure

that you are getting an even and square fold.

There is a skew adjustment on each plate to adjust for a

square fold on paper that is not cut square

(See figure 6.3-1).