13.5 Cleaning The Fold Stop Guides

The fold stop guides should be cleaned once a week

with a dry cloth to keep the plate moving properly.

13.6 Replacement Parts

To order replacement parts for your Flexifold 2nd

Station, contact Baumfolder.

Always be sure to give the model number and serial

number of your Flexifold to ensure receiving the proper
parts.

13.0 MAINTENANCE

13.1 Maintenance and Care of your Easyfold

The Flexifold 2nd Station has been designed to give

you years of useful service, provided you maintain it
according to these instructions.

13.2 Cleaning of Fold Rolls

Periodically wipe off the rubber surface of the fold

rolls using a solvent that is non-alcohol based.

13.3 Cleaning Filters

The filters on the pump should be checked periodi-

cally and cleaned as needed. The filters can be reached by
unscrewing the filter jars.

13.4 Photo Eyes

Occasionally wipe off both photo eyes with a dry

cloth.