Mechanical Load Sensor Test (Mechanical

Spring Ride): The test has the user verify the

expected measurement of the spring deflection

sensor. The program provides the reading of the

sensor.

Customer Scratch Pad: The tester is requested

to input data into the fields displayed on the screen.

This data will be stored in the ECU and also can be

stored to a file on the computer or printed out for

reference.

8. Where a safe location (e.g. restricted access area or

test track) is available, it is possible to road test the ABS

function by making an abrupt stop from a vehicle speed

of about 20 MPH to check for proper function. The

wheels should not enter a prolonged lock condition and

ABS function should be audible. It is the responsibility

of the technician to perform this test in a safe location.

ABS WIRING

All connector leads of the Bendix

®

TABS‑6

Adv MC

module pigtail harness are weather sealed at the connector

interface and are clearly labeled for proper installation.
Bendix provides over‑molded versions of the TABS‑6

wiring harness and Bendix recommends that the complete

harness be replaced if corrosion or damage occurs.
When troubleshooting ABS wiring, some general rules

should be followed where applicable.
1. Check all wiring and connectors to ensure they are

secure and free from visible damage (e.g. cuts,

abrasions, etc.).

2. Check for evidence of wire chafing due to poor routing,

or poor securing of wires.

3. Check connectors for proper insertion and locking.
4. Verify that the connector pins are properly greased with

a non‑conductive electrical grease compound.

5. Connector terminals must not show signs of corrosion

or exposure to the environment.

6. Never pierce wire insulation when checking for

continuity.

7. Do not deform individual pins or sockets during probing

with a volt/ohm meter.

8. It is strongly recommended that all wiring harnesses and

sensor leads are properly secured at least every 18 inches.

9. Apply a moderate amount of non‑conductive electrical

grease to each connector pin before reconnecting.