Relay valve – Bendix Commercial Vehicle Systems GEN 5 ABS User Manual

Page 30

Advertising
background image

30

Measure

Measure

Resistance

From:

To:

Range:

Common

Hold

3-8 Ohms

Common

Release

3-8 Ohms

Hold

Release

6-16 Ohms

PMV Resistance Test

Measure resistance at the PMV location
to check the valve.
Measure resistance at the appropriate
ECU harness connector pins to check
the cable and valve.
Note: Refer to the chart for pin
identification.

FIGURE 30 - PMV Harness Circuit Descriptions and Resistance Test

Looking Into Valve

No

Connection

Common

Hold

Release

1

3

2

Common

Hold

Release

1

3

2

Twist-Lock Connector

Threaded Connector

Twist-Lock

Connector

Threaded

Connector

FIGURE 29 - Typical PMV Circuit

Pressure Modulator Valve (PMV)
Troubleshooting

Follow the steps listed below to locate and correct ABS
modulator valve problems.

1. Access active trouble code(s) using either the Blink

Code procedure or the hand-held tester procedure.

2. Lookup the code description, the possible causes and

the repair procedures provided in this section.

3. Perform the recommended repair procedures.

4. After the repairs are completed, clear all codes and

check for any additional codes.

Relay

Valve

ECU

Advertising