3.4 ElECTRICal SUPPly TROUBlEShOOTING: POWER-UP SEqUENCE

Repair/replace the harness.

Reconnect all connectors.

Re-run the power-up test.

Repair/replace the harness.

Reconnect all connectors.

Re-run the power-up test.

NO,

the voltage is

out-of-range

NO,

the voltage is

out-of-range

The system must pass the electrical

pre-test before following these steps.

Clear the zone around the sensor of objects.

Ignition Power ON.

Test complete.

Test complete.

Do

both

LEDs illuminate

and remain ON?

Is

the

voltage between

10 and 14 volts?

YES

NO

NO

Observe the power-up

sequence. (See Table 1.)

Does

the power-up

sequence complete?*

YES

YES

YES

Power OFF. Disconnect harness at the

radar sensor (J2). Power ON.

Measure the voltage between Pins 1 and 2

of the harness connector J2.

Power OFF. Re-connect the harness at the radar sensor (J2).

Disconnect the harness at the Operator Display Unit (J1).

Measure the voltage between Pins 1 and 2 of the harness connector J1.

Power OFF.

Replace the Operator Display Unit.

Re-run the power-up test.

Both LEDs illuminate and remain ON.

Continue flowchart on next page at

.

Harness

Harness

Is

the

voltage in the range 10

to 14 volts?

* Do both the red and

yellow LEDs illuminate for

a half-second, followed

by the red LED remaining

on for a further 5 (five)

seconds, followed by the

yellow LED illuminating

and staying ON?

Advertising