5

Parallel with

the Ground

FIGURE 5 - inStallation of SenSor

1.4 OPERaTOR DISPlay UNIT mOUNTING

The Bendix BlindSpotter Operator Display Unit (ODU)

should be mounted on a windshield pillar for the side of

the vehicle being monitored - see Figure 6.

Mount on

Windshield

Pillar

FIGURE 6 - inStallation of odU

The Bendix BlindSpotter Operator Display Unit has a

bracket that is designed to be bent up to fifteen (15) degrees

in order to optimize the angle for the driver’s view.

1.1 RaNGE

See Figure 2. The effective range is approximately ten (10)

feet out from the vehicle and the detection zone extends

seven and a half feet forward and backward from the

sensor.

1.2 SENSOR lOCaTION

The Bendix

BlindSpotter

®

Side Object Detection Sensor

must be mounted on the side of the vehicle, between 22

and 36 inches from the ground and at least 18 inches rear

of the side view mirror (See Figure 4).
Note: To reduce the possibility of the sensor detecting

objects mounted to the vehicle — like the steps or fuel

tanks — make sure the face of the sensor extends out a

minimum of 5/16 of an inch further than any other object

within six (6) inches of the sensor’s body.

1.3 SENSOR ORIENTaTION

The Bendix BlindSpotter Sensor should be mounted on a

vertical surface and oriented so that the embossed logo

is parallel to the ground — you may use the lower two

mounting holes as a guide - see Figure 5. Orientation is

crucial for proper operation due to the radar’s polarized

beam profile.

Advertising