Automatic shut down, Measurement and monitoring of rf power, Measurement and monitoring of rf power 1 – Bird Technologies DA40 UHF Series-Manual User Manual
Page 33
 
Operating Instructions
19
Automatic Shut Down
When operations are completed, turn the RF power to the load off. The 
load fans will stay on until the load is cool, then they will shut off.
Measurement and Monitoring of RF Power
The Digital Air Series load may be used in conjunction with any of the 
Bird rigid coaxial line power meters. When fitted with the appropriate line 
section and wattmeter, the combination is a useful tool for tuning and 
adjusting a transmitter as well as monitoring RF power directly in watts.
Broadcasters involved in the transmission of high definition televi-
sion, digital audio broadcast, or other signals with complex modula-
tion should use Bird Broadcast Power Monitors (BPM) for the 
measurement of true average power in these systems. BPMs are also 
required in applications where multiple carriers are present in the 
transmission system simultaneously, as in the case of post combiner 
power measurements. Conventional broadcast power meters will pro-
duce erroneous readings in the presence of complex modulation due to 
the high peak to average power ratio of these signals. Contact a Bird 
sales representative for more information.