Chapter 5
Maintenance
Troubleshooting
For corrections requiring repair or replacement of components see the 
appropriate section. Only those functions within the scope of normal 
maintenance are listed. This manual cannot list all malfunctions that 
may occur, or corrective actions. If a malfunction is not listed or is not 
corrected by listed corrective actions, notify a qualified service center.
.
WARNING
Disconnect this unit from the RF power sources and
the AC line before any disassembly. The potential
for electrical shock exists.
Problem
Possible Cause
Possible Correction
Overtemperature 
interlock is active.
Overheating
Make sure air input and output 
openings are not restricted. See 
“Unit Placement” on page 7.
Reduce RF power.
One or more fans 
failing.
Make sure AC power is properly 
connected and turned on. See 
“AC Power Hookup” on page 12.
Contact the Bird Service Group for 
replacement. See “Customer 
Service” on page 23.
AC power interlock 
is active, or no “ON” 
indicator lit (neither 
automatic nor 
manual light).
No AC power
Make sure AC power is properly 
connected and turned on. See 
“AC Power Hookup” on page 12.
ON/OFF switch is off.
Turn the switch on.
Open circuit breaker.
Reset the circuit breaker.
High VSWR
Poor flange 
connection.
Make sure the flange connection 
is hooked up properly. See 
“Interlock Connection” on 
page 10.
One or more resistors 
failing.
Contact the Bird Service Group for 
replacement. See “Customer 
Service” on page 23.