Fault Location Mode
35
For example, for a cable with a dielectric constant of
2.296, the velocity percentage is 66%. If the cable is
100 feet long, then the Site Analyzer should be set to a
frequency span of 700 MHz. The resolution of the
graph will be 5 inches.
Press the
Mode key
Press from
Select Mode
Calibration: OFF
25.00
MHz
1700.00
99.99
1.00
V
S
W
R
Measure Match Mode
Save/
Recall
Auto
Scale
Limit
Test OFF
HOLD
Measure
Match
Fault
Location
Press the
Config key
Press to
display the
frequency
settings
Measure Match Mode
Start:
MHz
Stop: 1700.00 MHz
25.00
Center: 862.50 MHz
Span: 1675.00 MHz
Band List: Custom
25.00
MHz
1700.00
99.99
1.00
V
S
W
R
Freq
Scale
Limit
Line
Cable
Loss
Freq
Scale
Advertising