Note: Be very careful removing the iron pipe
plug, the threads in the socket hole are alumi-
num, and can be easily damaged.
4. Replace the plug with the ther-
moswitch. Use an acceptable pipe seal-
ing compound sparingly only on the
external threads of the thermoswitch.
+
Note: Do not contaminate the coolant with pipe
sealing compound.
5. Check the unit for coolant leaks.
While following the instructions for connecting the Ther-
moswitch, refer to figure 4.
1. Unscrew the larger knurled ring-nut
(A) at the lower end of the coupling
jack assembly. Pull it off from the
thermoswitch jack (B). Unscrew the
small knurled cover fitting (C) from
the base plug (D) of the connector to
release the base.
Bird Model 8329-300 Tenuline Attenuator
10
A
B
C
D
E
F
G
H
Figure 4
Thermoswitch
Assembly