Bird Technologies 8329-300 User Manual
Page 21

2. Thread the interlock wires through
the clamp (E) with the washers (F) in-
side and with its threaded fitting in
place.
3. Service the interlock wires with short
tips, use spaghetti sleeves over the
wire ends if needed.
4. Securely solder the interlock leads to
the lugs (G) of the connector base.
+
Note: Be sure that the larger captive clamping
nut (A) is in place over the base plug (D) with
the knurled end outward.
5. Screw on the cover ring (C) first, then
fasten the cable clamp (E) in place,
and tighten the two yoke screws (H)
on the cable. Push the plug back onto
the thermoswitch, and tighten the
captive knurled connecting ring. Do
not attempt to operate the equipment
without the interlock attached.
Blower
Assembly
For field installation of the blower assembly refer to the
blower instruction manual.
11
Operating Instructions