Bird Technologies 8640B Series User Manual
Page 21

Bird 8640 Series Moduload RF Load Resistor
10
y
Insert the center bullet and push it in until it is fully seated.
y
Connect the coaxial input in a straight line and push carefully on
the center conductor to close.
NOTE: The swivel flange on the load makes connection
independent of the orientation of the fixed flange on the coaxial
input outer conductor.
y
Insert the bolt sets and tighten evenly all around to transmission
line manufacturer’s recommended torque. Use all of the bolts.
Unflanged Coupling:
To couple the unflanged connector with an
unflanged RF line, use an appropriate coupling kit. Refer to Figure 5
while following the instructions below:
y
Insert the center bullet and bottom it on the midpoint nibs.
y
Position the outer sleeve, with clamping bands, over the input
connector.
y
Set the transmission line snugly against the coupling stops.
y
Position the clamping bands evenly about 3/4” from the ends of
the sleeve.
y
Tighten the clamping bands.
Figure 5
Unflanged
Coupling
RF COAXIAL
LINE
CLAMPING
BANDS
CONNECTOR
SLEEVE
BULLET
LOAD