Chapter 5 maintenance, Cleaning, Troubleshooting – Bird Technologies 4304A User Manual

Page 28: Cleaning troubleshooting

Advertising
background image

17

Chapter 5

Maintenance

The rugged and simple design of the Bird 4304A means that it requires minimal
routine maintenance.

Cleaning

It is important to keep the following surfaces clean:

Socket bore

DC contacts on the element

Teflon insulators

If any of the contacts or line connectors are dirty, clean them with a cotton swab
dipped in commercial contact cleaner or isopropyl alcohol.

If the RF line section seems dirty, do not loosen any connections. Clean accessible
components as described above and use dry, clean air to blow out the interior.

The outside of the meter housing can be cleaned with a soft cloth dampened
with a mild detergent solution. Do not wipe the meter glass with a dry cloth, or a
static charge could develop that would cause an erroneous meter indication.

Troubleshooting

The following table contains troubleshooting information for problems that can
occur during normal operation. Find the problem on the table, review possible
causes, and perform the corrective action listed.

WARNING

Never attempt to connect or disconnect RF equipment from the transmission

line while RF power is being applied.

Leaking RF energy is a potential health hazard.

CAUTION

Do not drop. Calibration could be disturbed or the meter could be damaged

as a result.

CAUTION

Do not attempt to remove the RF center conductor.

This will damage the line section.

Advertising