Table 7-22 specifications common to all sensors – Bird Technologies 4421 User Manual

Page 56

Advertising
background image

Bird 4421 RF Power Meter

44

Table 7-22 Specifications Common to all Sensors

Impedance, Nominal

50 ohms

Max. Allowable Terminating
VSWR

2.00:1

Calibration Technique

Frequency-specific calibration factors stored in
nonvolatile memory in each sensor.
Sensor output corrected for frequency and
temperature within specified ranges.

Calibration Cycle, Nominal

4027A and 4027F, 6 months
All other models, 1 year

Accuracy, Reflected

Calculated from FWD accuracy and FWD power

Accuracy, VSWR

Calculated from FWD and RFL power

Sampling Rate, Nominal

2 readings/second

Operating Power

Supplied by power meter via sensor cable

Connectors

4028B10M
4028C10M
4028A Series
All other models

1-5/8” EIA Flanged
3-1/8” EIA Flanged
7-16 DIN, LC, HN, or 7/8”
Customer specified from QC list, appropriate for
frequency and power.

CE

CE Compliant. Refer to Declaration of Conformity
for specific standards.

Humidity, Max.

95% (noncondensing)

Altitude, Max.

10,000 feet (3,000 m)

Temperature Range

Operating
Storage

0 to 50 °C (32 to 122 °F)
–20 to +70 °C (–4 to +158 °F)

Dimensions

4028B3M, 4028B10M
4028A Series
All other models

6.75”L x 3.5”W x 4.75”H (175 x 89 x 121 mm)
4.7”L x 3.2”W x 3.8”H (120 x 82 x 97mm)
5.2”L x 2.5”W x 3.25”H (137 x 64 x 83 mm)

Weight, Nominal

4028B3M, 4028B10M,
4028C10M

4028A2M, 3M, 4M, 10M,
and 25M

All other models

5 lb. 2 oz. (2.33 kg)

3 lb. 5 oz. (1.5 kg)

1 lb. 13 oz. (0.8 kg)

RFL Accuracy

FWD Accuracy

FWD Power

10

Directivity 10

/

---------------------------------

+

=

VSWR

1

P

R

P

F

------

+

1

P

R

P

F

------

=

Advertising