Bird Technologies 3140 Display User Manual

Page 24

Advertising
background image

Bird Electronics Corporation

14

* -

Peak to Average ratio is specified based on the fullscale

power of the specific TPM model. For example, a TPM with a

fullscale forward power rating of 1 kW will provide accurate

readings for signals with peak powers up to 10 kW. If the TPM is

operated below its fullscale power rating, the peak / average

rating will increase by the difference between the fullscale value

and the operating power. For example, if a 1 kW TPM is oper-

ated at 700 W, the new peak/ average ratio would be 11.5 dB.

Line Size

Power Range

Fullscale (kW)

7/8”

Very Low

Low

Medium

High

Very High

0.1
0.5
1.0
2.5
5.0

1 - 5/8”

Very Low

Low

Medium

High

Very High

0.5
1.0
2.5
5.0

10.0

3 - 1/8”

Very Low

Low

Medium

High

Very High

2.5
5.0

10.0
25.0
50.0

RF Specs

FWD / RFL Ratio

Reflected fullscale power is 1/10 of forward
fullscale power.

Peak/Average Ratio

10 dB min*

Main Line Insertion Loss

0.2 dB max, 0.08 dB typical

Main Line VSWR

1.1 max

Testport VSWR

1.5 max, 1.3 typical

Accuracy

± 5% of reading (2s) after zeroing sensor, if
calibrated by Bird. This does not include
user mismatch uncertainty and user
voltmeter uncertainty. If not calibrated by
Bird, add the uncertainty of the calibration
method and reference standard. Derate
accuracy by 1% if not at 25 ± 10 °C.

Dynamic Range

16 dB min

Directivity, Rfl

26 dB min, 30 dB typical

Measurement type

In-line, true-average power

Calibration

Unit can be calibrated by user by adjusting
pot to get 4V output for a fullscale RF input.

Recommended Cal Interval

1 year

Advertising
This manual is related to the following products: