Fade Mode

1. Use the <MENU> button to navigate to ShNd then press <ENTER>.

2. Then use the <UP/DOWN> buttons to display FAde then press <ENTER>.

3. Press the <UP/DOWN> buttons to navigate the speed setting from SP1

(slow) to SP8 (fast).

4. Press <ENTER>. The selected fade will start in 15 seconds.

Individual Pixel Group Intensity

Allows the user to adjust the intensity level of each grouping of LEDs. These settings are

global, they will effect all modes.

1. Use the <MENU> button to navigate to NAnu, then press <ENTER>.

2. Then use the <UP/DOWN> buttons to choose either red, Gree, bLue, or

Uhlt.

3. Press the <ENTER> button.

4. Use the <UP/DOWN> buttons to select from 0 (off) to 255 (100%).

5. Press the <ENTER> button to confirm.

Troubleshooting

Symptom

Solution

Fixture Auto-Shut

Off

Check the fan in the fixture. If it is stopped or moving slower than

normal, the unit may have shut itself off due to high heat. This is to

protect the fixture from overheating. Clear the fan of obstructions,

or return the unit for service.

Beam is Dim

Check optical system and clean excess dust/grime. Also ensure that

the 220V/110V switch is in the correct position, if applicable.

No Light Output

Check to ensure fixture is operating under correct mode, IE sound

active/auto/DMX/Etc., if applicable.

Chase Speed Too

Fast/Slow

Check to ensure proper setup of speed adjustment.

No Power

Check fuse, AC cord and circuit for malfunction.

Blown Fuse

Check AC cord and circuit for damage, verify that moving parts are

not restricted and that unit’s ventilation is not obstructed

Slow Movement

Verify that 220V/110V switch is in the correct position, if applicable.

Also check that speed channels are set appropriately.

No Response to

Audio

Verify that the fixture is in “Sound Active” mode.

Adjust Audio Sensitivity, If Applicable.

Fixture Not

Responding /

Responding Er-

raticly

Make sure all connectors are seated properly and securely.

Use Only DMX Cables and/or check cables for defects

Install a Terminator.

Reset fixture(s).

Intermittent

Lamp

Check lamp for properly installation.

Relamp, lamp may have reached end of life.

Remote Doesn’t

Work

Verify remote control cable is installed properly and securely.

Verify remote is correct type (CA-9 or other as applicable.)

Fixture Moving

On Its Own

Verify proper mode of operation. Is the fixture in “Auto” mode?

If your problem persists or isn’t listed contact [email protected].