3 configuration command string – Brady 1024 User Manual
Page 30

24
Printing Labels
2.3
Configuration Command String
The Configuration Command String sets the operating parameters of the
Printer. The Command Strings are described below.
<STX>KDwxy
<CR>
where w:
Bit #
Function
Value
0-2
Baud Rate
0=9600, 1=600, 2=2400, 3=19200, 4=4800, 5=N/A,
6=1200, 7=9600 Test Mode
3
Word Length
0=8 bits, 1=7bits
4&5
Unused
Set to 0
6
Always 1
Set to 1
7
Always 0
Set to 0
where x:
Bit #
Function
Value
0
Print Method
0=direct, 1=transfer
1
Present Sensor
0=not equipped, 1=equipped
2
Alternate Char.
Set
0=standard, 1=main frame
3
Cutter
0=disabled, 1=enabled
4&5
Unused
Set to 0
6
Always 1
Set to 1
7
Always 0
Set to 0
where y:
Bit #
Function
Value
0&1
Paper Type
0=gap(edge), 1=reflective, 2=continuous (3")
2
Linerless
0=not equipped, 1=equipped
3-5
Unused
Set to 0
6
Always 1
Set to 1
7
Always 0
Set to 0
Example:
<STX>KD @A@
<CR>
@
Sets the Printer to: 9600 baud; 8 bit word length/no parity.
A
Sets the Printer to: thermal transfer; no present sensor; standard
character set; no cutter.