Especificacion, Warning – Briggs & Stratton 020330-0 User Manual

Page 21

Advertising
background image

21

2. Carefully remove foam pre-filter (C) and paper filter (D).

3. Wipe clean inside of base (E) and cover thoroughly.

4. To clean or replace the foam pre-filter, wash pre-filter

in a solution of household detergent and warm water,
then rinse thoroughly. Squeeze dry in a clean cloth.

5. Saturate foam pre-filter in clean engine oil and squeeze

in a clean, absorbent cloth to remove all excess oil. DO
NOT twist.

IMPORTANT: The engine will smoke during initial start-up if
too much oil is left in the pre-filter.

6. Clean paper filter by tapping it gently on a solid surface.

If the paper filter is too dirty, replace it with a new one.
Dispose of the old filter properly.

7. Insert the foam pre-filter into the air cleaner cover, then

the paper filter.

8. Assemble air cleaner cover onto base and tighten

screws.

Service Spark Plug

Change the spark plug every 100 hours of operation or once
each year, whichever comes first. This will help your engine
to start easier and run better.

1. Clean area around spark plug.

2. Remove and inspect spark plug.

3. Check electrode gap with wire feeler gauge and reset

spark plug gap to recommended gap if necessary (see
Specifications).

4. Replace spark plug if electrodes are pitted, burned or

porcelain is cracked. Use the recommended
replacement spark plug. See Specifications.

5. Install spark plug and tighten firmly.

Clean Cooling System

Over time debris may accumulate in cylinder cooling fins and
cannot be observed without partial engine disassembly. For
this reason, we recommend you have a Briggs & Stratton
authorized dealer clean the cooling system (F) per
recommended intervals (see Maintenance Schedule in the
Maintenance section). Equally important is to keep top of
engine free from debris. Also see Cleaning.

Check Valve Clearance

Regular valve clearance check and adjustment will improve
performance and extend engine life. This procedure cannot
be done without partial engine disassembly and the use of
special tools. For this reason we recommend that you have
an authorized dealer check and adjust valve clearance at
250 hours or as recommended (see Maintenance Schedule in
the Maintenance section).

Spark Arrester Service

Your engine is not factory-equipped with a spark arrester. In
some areas, it is illegal to operate an engine without a spark
arrester. Check local laws and regulations. A spark arrester is
available from your nearest Briggs & Stratton Authorized
Dealer.The spark arrester must be serviced every 50 hours to
keep it functioning as designed.

If the engine has been running, the muffler will be very hot.
Allow the muffler to cool before servicing spark arrester.

A

B

C

D

E

F

WARNING

Contact with muffler area can result in serious
burns.

Exhaust heat / gases can ignite combustibles,
structures or damage fuel tank causing a fire.

• DO NOT touch hot parts and AVOID hot exhaust gases.

• Allow equipment to cool before touching.

• Keep at least 5 feet (1.5 m) of clearance on all sides of pressure

washer including overhead.

• Code of Federal Regulation (CFR) Title 36 Parks, Forests, and

Public Property require equipment powered by an internal
combustion engine to have a spark arrester, maintained in
effective working order, complying to USDA Forest service
standard 5100-1C or later revision. In the State of California a
spark arrester is required under section 4442 of the California
Public resources code. Other states may have similar laws.

Advertising