Electrical connection test the installation – Bosch NEM 95 User Manual

Page 6

Advertising
background image

6

Place cooktop into cutout. Insert clamping screw into the bracket and secure

cooktop to countertop.

Use a wood block to protect fragile countertop materials.

d CAUTION: Before installing, turn power OFF at the service panel. Lock sevice

panel to prevent power from being turned ON accidentally.
The branchĆcircuit breakers ampacity , the wire sizes and the connections must be

conform to the requirements of the National Electrical Code or Canadian Elektrical

Code and all local codes and ordinances.

Connect only to a 3Ćwire, 120/240Ćvolt power supply; the neutral conductor is not

required for the operation of the appliance. The potential at the power supply

electrical connections shall be 150ĆvoltĆtoĆground or less.

Attach flexible conduit to the junction box.

d CAUTION: To reduce the risk of electic shock and fire, do not use a flexible

powerĆsupply cord.

Connect the cooktop lead wires to the junction box supply wires in proper phase:

black (L1) to black

red (L2) to red

green wire to ground

Remove everything from the cooktop surface.
Clean cooktop surface with cooktop cleaning creme.

Turn on power supply.

Verify that elements function properly.

Electrical connection

Test the installation

Advertising
This manual is related to the following products: