INSTALLATION GUIDE

K-RANGE 24™ INLINE LED REMOTE CONTROLLER

2 of 2

IG022614-1.0

Fixture does not illuminate

• Ensure the system is wired correctly.

• Verify polarities are correct.

• Ensure a compatible constant voltage dimmable fixture is installed.

• Ensure a compatible constant voltage driver is installed.

• Ensure the driver and fixture have the same voltage specifiations (12V & 12V, or 24V & 24V).

Fixture does not dim

• Ensure a compatible constant voltage dimmable fixture is installed.

• Ensure remote is paired with receiver.

Fixture is flashing or flickering

• Verify a compatible constant voltage driver is installed.

• Ensure a compatible constant voltage dimmable fixture is installed.

• Ensure all connections are properly secured.

• Ensure no more than a single controller is attached to each driver output.

Fixture is slowly flashing

• Ensure driver is not overloaded. An overloaded driver will cause the internal auto-reset of the driver

to trip repeatedly.

Correct colors are not illuminating

• Verify the correct leads are connected to the correct terminals on the receiver.

• Ensure potential leads at opposing end of fixture are not crossed.

Unable to pair remote with receiver

• Ensure the battery of the remote is not drained.

• Read the installation instructions on page 1 thoroughly.

• Reset the receiver to factory settings.

Remote Operation

Speed / Brightness Adjustment

Adjust static brightness or dynamic mode speed

(15 static brightness or 7 speed levels).

Touch Pad

Adjusts Kelvin (color temperature).

Dynamic Mode

Fades from warm to cool kelvin. Use

(+) and (-) to adjust 7 speed levels.

Power

B

G

R

V+

DC+

DC−

Power

Address

Setting

N

U

R

Input From

12-24VDC Driver

Running Light

To Low Voltage

LED Load*

Receiver

CW

WW

NW

V+

W

W

W

V+

Address Setting

*Utilize V+, WW, & NW terminals for 2-channel K-RANGE fixtures.

OUTPUT

Wiring Connections

Troubleshooting

Prior to troubleshooting, ensure a compatible system is installed. Verify compatible fixtures, drivers, controls and additional components were specified

correctly.

For additional questions/concerns, contact technical support. Please have all part numbers on hand for fast and efficient technical assistance.

Determine the number of low voltage outputs of the driver when installing multiple PWM controllers. No more than one PWM controller can be attached to

a single output of the driver.