www.DiodeLED.com

INSTALLATION GUIDE

®

[email protected]

www.DiodeLED.com

2 OF 3

REIGN™ 12-24V TOUCH DIMMER SWITCH

Install Additional Components, Verify Connections, and Turn

Main Power ON at Breaker.

6

ON

OFF

OFF

OFF

ON

ON

OFF

OFF

ON

ON

If system remains unresponsive or is working improperly, turn OFF

main power at breaker and verify all connections. Review the ‘Wiring

Connections’, ‘System Diagrams’, and dimming control installation guides.

Replace wiring back into wall box. Break off appropriate fins

when ganging multiple dimmers. Screw dimmer and faceplate

to wall box.

5

Never install low and high voltage wiring in the same wall box. A physical

divider must exist when ganging low voltage and high voltage controls.

To detach a fin, grip with pliers and bend back/forth until it detaches.

Unlike high voltage dimmers,

de-rating the dimmer maximum load is not

required when ganging low voltage controls.

* Driver may not require a fault ground connection. Refer to driver

specifications for additional information.
*** Install a Class 2 constant voltage driver compatible with a low voltage

PWM controller.
**** No more than one PWM controller/dimmer switch can be attached

to a single output of the driver.

‡ Refer to driver specifications for a compatible junction box.
‡‡ See fixture specifications for maximum series run limits.

The following diagram is provided as an example system design. Class 2 compliance requires a Class 2 driver per REIGN dimmer (e.g. 60W @ 12V, 96W

@ 24V). Install in accordance with the NEC, and local regulations.

AC Power

50/60Hz

L

N

V- (Black)

Input

Output

V+ (Red)

G*

N

L

Input

Output

V+
V-

Class 2 Low Voltage Driver****

Installed in Junction Box‡

Ins

tall applic

able wire gauge / type

V+

V-

LED Tape Light / Fixture‡‡

REIGN 12-24V Dimmer****

Installed in Switch Box

V+

V-

System Diagram