Dynalite MH2065v User Manual

Dynalite lighting controls and system accessories

Advertising
background image

DYNALITE INC

1050 Commerce Ave ● Union ● NJ ● 07083

908-687-8800 Phone ● 908-686-6682 Fax

www.dynalite.com

Dynalite Lighting Controls and

System Accessories

Instruction Manual

For Model MH2065v

Fan Cooled Strobe Head

Replacement of Modeling Lamp

1. Unplug the flash head

from the power pack
and allow the flash
head to cool before
touching the modeling
lamp.

2. Remove flash head

accessories if present.

3. Remove the flash tube from the head in or-

der to reach the modeling lamp.

4. Remove the modeling lamp by carefully

griping it with a soft cloth and pulling
straight out.

5. Install the new lamp by aligning the pins

with the socket and press the lamp in place.

Please note: Do not touch the new lamp with your hands.
Oils from your hands can cause premature failure of the
lamp or could cause an unexpected shattering of the lamp.

Replacement of the Flash Tube

1. Unplug the flash head

from the power pack
and allow the flash head
to cool before touching
the flash tube.

2. Remove flash head ac-

cessories if present.

3. Remove the flash tube by rocking and or

pulling the outer edge of the reflector as-
sembly out of the flash housing.

4. Install the new flash tube assembly by align-

ing the three connection pins with the three
connection sockets inside the flash housing.
Ensure that the connection pins are aligned
correctly and in the proper configuration
before installing the flash tube assembly.
Gentle push the reflector/flash tube assem-
bly until the edge of the reflector is flush
with the outer edge of the flash housing.

Note: Use only the appropriate flash tube.

RR-GH

RR-4G

RR-AFBD

RR-AF

RR-50

RR-80

RR-AR

SR-65SN

UCBW-36
UBBW-44

UQSS-48

R-11/20/2013

Advertising