Page 5

DO NOT adjust this valve!

(Located beside Solenoid Valves)

. Lower the platform to the ground level loading position.

2. Remove the pump cover.

3. Turn the adjustment screw (shown below) counter clockwise until the outer barrier does not raise

when the Up button is pressed.

4. Turn the adjustment screw clockwise in /4 turn increments until the outer barrier raises and fully

locks in position when the Up button is pressed. DO NOT turn the adjustment screw beyond this

position.

5. Verify the outer barrier will not raise when occuppied.

6. Reattach the pump cover.

UP

DOWN

3281

9

FOLD

UNF

OLD

3282

0

®

1. Position the platform at the floor level loading

position.

2. Loosen the hex nut on the adjustment screw (do

not remove hex nut).

3. Turn the adjustment screw counter clockwise

until the platform does not fold when the Fold

button is pressed.

4. Turn the adjustment screw clockwise in /4 turn

increments and press the Fold button until the

platform folds completely (Note: return the plat-

form to floor level position after each attempt to

fold the platform).

5. Turn the adjustment screw an additional /8 turn

after the platform folds successfully.

6. Tighten the hex nut without moving the adjust-

ment screw.

7. Verify the platform will not stow while occupied.

Platform Fold Pressure Adjustment

Outer Barrier Fold Pressure Adjustment

Platform Fold

Adjustment

Allen Screw

Note: Secure adjustment

screw and tighten hex

nut following adjustment.

Outer Barrier

Fold Adjustment