Specifications, Replacing uv lamp and servicing uv system, Maintenance suggestion – Watts PWUVQ User Manual

Page 3: Operating conditions, Replacement parts

Advertising
background image

3

Specifications

Notes: Line cord and lamp lead wire omitted for clarity .

Product code

Flow rate

(GPM)

PiPe Size

diMenSionS

(l X w X H)

electrical

SHiPPinG

(lbS.)

PWUV2110

2

1

2

" MNPT

18" x 6" x 5

3

8

"

110-130 v / 50-60 Hz

6

PWUV2220

2

1

2

" MNPT

18” x 6” x 5

3

8

"

200-250 v / 50-60 Hz

6

PWUV6110

6

3

4

" MNPT

25

1

2

" x 6” x 5

3

8

"

110-130 v / 50-60 Hz

7

PWUV6220

6

3

4

" MNPT

25

1

2

" x 6” x 5

3

8

"

200-250 v / 50-60 Hz

7

PWUV8110

8

3

4

" MNPT

32" x 8

1

4

" x 3

3

4

"

110-130 v / 50-60 Hz

9

PWUV8220

8

3

4

" MNPT

32" x 8

1

4

" x 3

3

4

"

200-250 v / 50-60 Hz

9

PWUV12110

12

1" MNPT

41

1

2

" x 8

1

4

" x 3

3

4

"

110-130 v / 50-60 Hz

17

PWUV12220

12

1" MNPT

41

1

2

" x 8

1

4

" x 3

3

4

"

200-250 v / 50-60 Hz

17

Replacing UV Lamp and Servicing

UV System

Note: Avoid touching the sides of the quartz sleeve and lamp,

handle by the ends only.

Step 1 Disconnect power .
Step 2 Turn water off and open valve downstream of system to

relieve pressure .

Step 3 Remove vinyl cap and unscrew the nut .
Step 4 Carefully withdraw lamp approximately 2 inches from

chamber .

Step 5 While holding lamp end carefully remove lamp socket on

end now exposed .

Step 6 Carefully withdraw lamp from chamber .
Step 7 Carefully remove O-ring from the end of quartz sleeve .
Step 8 Carefully remove quartz sleeve .
Step 9 To reinstall follow Steps 8 through 1 in reverse .

Maintenance Suggestion

To operate the sterilizer properly and attain its maximum efficiency,

the following maintenance is recommended:
1 . Quartz sleeve cleaning or replacement:
a) Quartz sleeve is to be cleaned every 6-12 months, clean with

glass cleaner .

b) Quartz sleeve is to be replaced every 24 months .
2 . UV lamp replacement is recommended every 8000-9000 hours

of operation (approx . 12 months of continuous service) .

CAUTION: Ultraviolet lamp and quartz sleeve are easily dam-

aged. Pay attention when removing or replacing lamp and

quartz sleeve.

Operating Conditions

Maximum Operating Pressure: 125psi (8 .9 bar)
Maximum Operating Temperature: 104°F (40°C)
Minimum Operating Temperature: 36°F (2°C)
UV Dose At End Of Lamp Life (1 year or 9,000 Hours): 30mj/cm

2

Maximum Iron: Less Than .3 PPM
Maximum Manganese: Less Than .05 PPM
Maximum Turbidity: Less Than 5 NTU
Maximum Hydrogen Sulfide: Less Than .05 PPM
Maximum Hardness: Less Than 7 Grains Per Gallon as CaCO

3

Flow

rate

(GPM)

bulb Model

ballaSt Model

Quartz SleeVe Model

2

PWUVBULB2

PWUVBAL2

PWUVQS2

6

PWUVBULB6

PWUVBAL6-12

PWUVQS6

8

PWUVBULB8

PWUVBAL6-12

PWUVQS8

12

PWUVBULB12

PWUVBAL6-12

PWUVQS12

Replacement Parts

Advertising