System specifications, Filter cartridge life span, Notice to installer – Watts PWICE3 User Manual

Page 2: Installation precautions, Replacement filter pack

Advertising
background image

2

System Specifications

Maximum Pressure: 125psi (8 .6 bar)
Maximum Temperature: 100°F (38°C)
Inlet/Outlet Connections: ½" (15mm) FNPT
Maximum Flow Rate: 4 GPM

Filter Cartridge Life Span

Filter cartridges should be changed at 10,000 gallons, 15psi overall

system pressure drop at normal flow rate, or 6 months, whichever

comes first .

Please note: Cartridge capacities are estimates and may be less

depending on incoming water quality . Cartridges should be changed

at least every 6 months .

Notice to Installer

• Do not discard this manual after installation. This manual contains

important operation, maintenance and precautionary information .

Please present this manual to the user/owner/operator after instal-

lation .

• It is strongly suggested that you read this manual before installing

system to ensure the best possible installation .

• Installation must comply with all local and state plumbing codes

and regulations .

• Connect the system to cold water supply only. Water Temperature

cannot exceed 100°F (38°C) .

• System must be installed in a vertical, upright and level position.
• Do not use with water that is microbiologically unsafe or of un-

known water quality .

• Notice to user/owner/operator: Please retain this manual for future

reference for parts, maintenance, or troubleshooting .

• It is recommended that all personnel responsible for operation and

maintenance of this product read the precautions, maintenance,

and operation sections of this manual .

Installation Precautions

• Do not install system on line pressure above 125 psi (8.6 bar).
• Do not install the system on a hot water line. Failure to limit the

water temperature to 100°F (38°C) can result in housing failure and

property damage .

• Do not connect the system backwards with the feed water line

connected to the outlet .

• Do not use liquid pipe thread compounds for threaded connec-

tions . Use Teflon

®

tape only .

• Do not solder plumbing connections that are attached to the hous-

ings or inlet/outlet fittings . System damage may occur due to high

temperature .

• Do not allow the system to freeze. Turn off water supply and drain

the system if temperature falls below 32°F (0°C) .

• Do not install system in direct sunlight or where the system will be

exposed to harsh chemicals or may be subjected to being hit by

moving equipment, carts, mops, or any other item that may cause

damage .

• Allow 3" (76mm) minimum clearance under the housings for filter

replacement .

• If water hammer is evident, install water hammer arrestors before

the system .

• Do not over tighten fitting connections.
• Always back up valves and fittings with a wrench when installing

fittings to avoid over tightening or loosening existing fittings .

• Do not install the unit behind equipment where it may be difficult to

access the system for future filter replacements .

Position the system in a suitable location . The direction of flow

through the system is left to right . Keep this in mind when determin-

ing installation locations . Do not mount the system near any source

of heat. Also do not mount this system over anything that may be

adversely affected by water .

Teflon

®

is a registered trademark of E.I. Dupont de Nemours & Company.

Replacement Filter Pack

Model

Frequency

description

PWFPKICE3

6 Months

10" Sediment filter
20" Carbon Block filter (2 required)
10" Phosphate filter

note: Water conditions may require more frequent cartridge replacement