DIMENSIONAL DRAWING — 558D090-150

UNIT
558D

CORNER WEIGHT*

DIMENSIONS

A

B

C

D

‘‘H’’

‘‘J’’

‘‘K’’

Lb

Kg

Lb

Kg

Lb

Kg

Lb

Kg

Ft-in.

mm

Ft-in.

mm

Ft-in.

mm

090

164

74

140

64

208

94

243

110

1-2

7

8

378

3-5

5

16

1050

2-9

11

16

856

102

165

75

141

64

209

94

245

111

3-3

7

8

1013

3-5

5

16

1050

2-9

11

16

856

120

199

90

170

77

252

114

294

134

2-5

7

8

759

4-1

5

16

1253

3-0

3

8

924

150

202

92

172

78

256

116

300

136

1-2

7

8

378

4-1

5

16

1253

3-0

3

8

924

*Weights are for unit only (aluminum plate fins) and do not include options or crating.

NOTES:
1. Dimensions in [

] are in millimeters.

2.

Center of gravity.

3.

Direction of airflow.

4. Ductwork to be attached to accessory roof curb only.
5. Minimum clearance (local codes or jurisdiction may prevail):

a. Bottom to combustible surfaces (when not using curb) 0 inches. On horizontal discharge units with

electric heat 1 in. clearance to ductwork for 1 ft.

b. Condenser coil, for proper airflow, 36 in. one side, 12 in. the other. The side getting the greater clear-

ance is optional.

c. Overhead, 60 in. to assure proper condenser fan operation.
d. Between units, control box side, 42 in. per NEC (National Electrical Code).
e. Between unit and ungrounded surfaces, control box side, 36 in. per NEC.
f. Between unit and block or concrete walls and other grounded surfaces, control box side,

42 in. per NEC.

g. Horizontal supply and return end, 0 inches.

6. With the exception of the clearance for the condenser coil and combustible surfaces as stated in

Notes 5a and b, a removable fence or barricade requires no clearance.

7. Units may be installed on combustible floors made from wood or class A, B, or C roof covering material.
8. The vertical center of gravity is 1

Ј

-7

1

2

Љ

[495] for 090 and 102, 2

Ј

-0

Љ

[610] for 120 and 150 up from the

bottom of the base rail. Horizontal center of gravity is shown.

BOTTOM POWER CHART, THESE HOLES REQ’D FOR USE

WITH ACCESSORY PACKAGES — CRBTMPWR001A00

(

1

2

؆

,

3

4

؆

) OR CRBTMPWR002A00 (

1

2

؆

, 1

1

4

؆

)

THREADED CONDUIT

SIZE

WIRE SIZE

REQ’D HOLE

SIZES (MAX.)

1

2

؆

24 v

7

8

Љ

[22.2]

3

4

؆

POWER†

1

1

8

Љ

[28.4]

1

1

4

؆

POWER†

1

3

4

Љ

[44.4]

†Select either

3

4

Љ

or 1

1

4

Љ

for power, depending on wire size.

CONNECTION SIZES

A

1

3

8

Љ

Diameter [35] Field Power Supply Hole

B

2

1

2

Љ

Diameter [64] Power Supply Knockout

C

1

3

4

Љ

Diameter [44] Charging Port Hole

D

7

8

Љ

Diameter [22] Field Control Wiring Hole

E

3

4

Љ

-14 NPT Condensate Drain

F

2

Љ

Diameter [51] Power Supply Knockout

7