Installation/feedwater parameters, Dimensions - weights, Power – Watts PWBWIRON User Manual

Page 2

Advertising
background image

Installation/Feedwater Parameters

Location: Indoors (Protect from direct sunlight)
Minimum inlet pressure: 30 psig
Maximum operating pressure: 80 psig
Minimum water temperature: 34°F (1°C)
Maximum water temperature: 110°F (43°C)
pH Range 6.0-9.0
Iron Concentration Maximum 10 PPM
Manganese Concentration Maximum 5 PPM
Hydrogen Sulfide Concentration Maximum 3 PPM

C

A

B

D

E

Dimensions - Weights

ES-WQ-PWBWIRON 1225

© 2012 Watts

USA: Tel. (800) 224-1299 • www.watts.com

Canada: Tel. (888) 208-8927 • www.watts.ca

A Watts Water Technologies Company

MoDEl

VAlVE

MINERAl TANK

MEDIA CUBIC

GARNET No.12

SERVICE FloW

PRESSURE DRoP

BACK WASH

FlooR SPACE

SIzE

FooT

(lBS)

(GPM)

(PSI)

(GPM)

(l X W X H)

PWBWIRON1

Time Clock

9" x 48"

1

14

6

<15

7

16" x 15" x 55"

PWBWIRON15

Time Clock

10" x 54"

1.5

14

9

<15

8

16" x 15" x 62"

PWBWIRON2

Time Clock

12" x 52"

2

42

12

<25

12

17" x 15" x 60"

PWBWIRON3

Time Clock

13" x 65"

3

56

18

<25

15

18" x 15" x 74"

PART No.

TANK

IN

oUT

oVERAll HEIGHT

oVERAll DEPTH

SHIPPING WEIGHT

(A&B)

(E)

(E)

(C)

(D)

lbs.

kgs.

PWBWIRON1

9" x 48"

51"

51"

57"

16"

150

68

PWBWIRON15

10" x 54"

57"

57"

63"

16"

207

94

PWBWIRON2

12" x 52"

56"

56"

61"

16"

295

134

PWBWIRON3

13" x 65"

67"

67"

73"

16"

493

224

Power

Voltage: 120VAC
Frequency: 60Hz

Note: Peak service flow rate is for intermittent use only and is not to be interpreted as continuous service flow rate capability. These

systems are designed to treat the domestic water used in a single family dwelling. For irrigation water treatment or higher volume

applications please contact your Watts representative.

Advertising