640t – Installation and Operating Instructions

c

ontrol

p

anel

Fig. 5-13. Control Panel.

A. Ready Indicator

The Ready Indicator informs the operator that the
machine has reached the desired set temp of the Top
Main Roller.

B. Temperature Display

The Temperature Display shows the Set Temperature
of the laminator.

C. Speed Display

The Speed Display shows the set speed of the
laminator.

A

B

C

D

E

F

G

H

I

J

K

L

M

t

emp

s

ection

D. MES (Measure)

Press

MES to show the actual Top Main

Roller Temperature.

E. Temp Arrow Up

To increase the Top Main Roller temperature,
press and hold.

F. Temp Arrow Down

To decrease the Top Main Roller temperature,
press and hold.

G. HOT

For the factory preset temperature of the Top
Main Roller, press

HOT.

H. COLD

For the factory preset temperature of the Top
Main Roller, press

COLD

s

peed

s

ection

I. Speed Arrow Up Symbol

To increase the Roller speed, press and hold.

J. Speed Arrow Down Symbol

To Decrease the Roller speed, press and hold.

K. RUN

Press and release

RUN for continuous running.

L. STOP

Press

STOP to stop the machine.

M. REV (Reverse)

Press and hold

REV to reverse the direction of the

rollers. Release REV to stop. When in the reverse
mode, the machine will operate at 3 fpm, (0.9mpm)