Safe, Keep it, Danger – Human Touch iJoy 300 Robotic Massage Chair User Manual

Page 3: Warning, Save these instructions, Grounding instructions, Grounding methods, For all grounded cord-connected products

Advertising
background image

5

4

www.ijoy.com

KEEP IT

SAFE

DANGER:

To reduce the risk of electrical shock

Always unplug this product from the electrical outlet immediately after using and before cleaning.
Do not reach for this product if it has fallen into water. Unplug immediately.

WARNING:

To reduce the risk of burns, fire,

electric shock or injury to persons

Read all instructions before using this product.

WARNING:

Do not put hands or fingers near the massage mechanism or rollers while

this product is running. Touching the mechanism can result in injury from the rollers squeezing together.

This product should never be left unattended when plugged in.
Unplug from outlet when not in use, and before putting on or taking off parts.
Do not operate under blanket or pillow. Excessive heating can occur and cause fire, electric shock, or injury
to persons.
Close supervision is necessary when this product is used by, on, or near children, invalids, or disabled persons.
Use this product only for its intended use as described in this manual. Do not use attachments not
recommended by the manufacturer.
Never operate this product if it has a damaged cord or plug, if it is not working properly, if it has been dropped
or damaged, or dropped into water. Return this product to a service center for examination and repair.
Always keep the power cord away from heated surfaces.
Never operate this product with the air openings blocked. Keep the air openings free of lint, hair, and the like.

Never drop or insert any object into any opening.
Do not use outdoors.
Do not operate where aerosol (spray) products are being used or where oxygen is being administered.
To disconnect, turn all controls to the OFF position, then remove plug from outlet.
Do not massage abdomen when pain is present or if you are pregnant.
Do not massage any area of the body that is swollen, inflamed or covered with skin eruptions. Do not use on
unexplained calf pain.
Do not use this product when standing on a damp floor, or when any part of the body is in contact with plumbing
or any similar ground.
Always connect this product to a properly grounded electrical outlet.
This product is designed to operate on standard 120 Volt 60 Hz house current.
Do not use this product if noise above normal sound is heard.
This product is designed for personal in-home use. Commercial use will void warranty.

SAVE THESE INSTRUCTIONS

Comfortable clothing is recommended while using this product.

This product was meant to be used in a relaxed position. Never force any body part into the backrest area

while the rollers are moving.

Do not allow children to use this product.

If you feel any abnormal discomfort during the operation of this product, turn off the power immediately and do
not use the product. Consult your physician.

Do not sit on the controller.

Do not pull on the AC cord.

Always confirm that there are no obstacles behind the product and that there is sufficient space to recline.

When using this product after it has been in storage, check to see that the product is operating properly prior to

sitting in the product.

• Do not attempt to repair this product yourself.
If a malfunction occurs, please contact Interactive Health

at (800) 355-2762.

Safety Precautions

Grounding Instructions:

This product must be grounded. If it should malfunction or breakdown, grounding provides a path of
least resistance for electrical current to reduce the risk of electric shock. This product is equipped with
a cord having an equipment-grounding conductor and a grounding plug. The plug must be plugged into
an appropriate outlet that is properly installed and grounded in accordance with all local codes and
ordinances.

WARNING:

Improper connection of the equipment-grounding

conductor can result in a risk of electronic shock. Check with a qualified
electrician or serviceman if you are in doubt as to whether this product
is properly grounded. Do not modify the plug provided with the product
– if it will not fit the outlet, have a proper outlet installed by a qualified
electrician.

This product is for use on a normal 120-volt circuit and has a grounding plug that looks like the
plug illustrated in sketch (A). A temporary adapter that looks like the adapter used in sketches (B)
and (C) may be used to connect this plug to a 2-pole receptacle as shown in sketch (B), if a properly
grounded plug is not available. The temporary adapter should be used only until a properly grounded
outlet (sketch A) can be installed by a qualified electrician. The green colored, rigid ear tab or the like
extending from the adapter must be connected to a permanent ground such as a properly grounded
outlet box cover. Whenever the adapter is used, it must be held in place by a metal screw.

WARNING:

This product is equipped with a thermal resetting protection device. This is an

added safety feature to protect you and this product from overheating. If the product should suddenly
stop and will not start, turn the main power switch, located on the back of the product, off and do not
operate the product for at least 30 minutes. Failure to turn the product off may result in the product
starting unexpectedly when the device cools.

Grounding methods:

Grounded

Outlet

Grounded

Pin

(A)

(C)

(B)

Grounded

Outlet Box

Adapter

Metal

Screw

Tab for

Grounding Screw

For all grounded cord-connected products:

Advertising